High Performance AC Preamplifiers
for Evoked Potentials, EEG, EMG, ERG - Model P511 Series

Two versions of this high performance AC amplifier feature high gain, adjustable filters, low noise and an output which is easily interfaced with peripheral devices such as computers, oscilloscopes and recorders. All models require an external power supply.

For low impedance electrodes, connection may be made directly to the P511 via the standard input cable supplied. An optional high impedance probe provides an excellent interface for high impedance microelectrodes.

All models are CSA/UL listed for medical device safety.

 

MODELS P511 & CP511

The Model P511 has been the neurophysiologists' workhorse for extracellular recordings from nerve and muscle for years. EMG, EEG, ECG and ERG are just a few of the types of signals that can be recorded using the P511. The P511 is packaged as a 19" rackmountable amplifier, 1.75" high.

The CP511 shares all of the superior features with the P511, but is packaged for portable bench-top use. The unit is enclosed in a compact, rugged all-metal cabinet that is easy to stack vertically or horizontally. Optional rackmount hardware allows two units to be mounted side-by-side in a standard 19" rack while using only 3.5" of vertical space.

An optional, very low leakage input cable is available for additional safety in high-risk environments. The cable features less than 3 µA leakage current at 120 VAC, 60 Hz (for use with P511 and CP511 only).

SPECIFICATIONS FOR ALL P511 SERIES AMPLIFIERS
Amplification
Amplification   50 minimum to 200,000 maximum
Amplification Settings   6-position step switch.
Settings of 5, 10, 20, 50, 100, and 200;
And 2-position switch, X10 and X1000
Vernier Control   Attenuates amplification settings 3 times
Filters
Low Filter   2-pole (-12 dB/octave): 0.01, 0.1, 0.3, 1, 3, 10, 30, 100, and 300 Hz
High Filter   4-pole (-24 dB/octave): 0.03, 0.1, 0.3, 1, 3, and 10 kHz
Line Filter   Notch-type filter (50/60 Hz), switch selectable
Input Characteristics
Input Impedance   20 Mohm, differential, 35 pF at connector per terminal
CMR (Common-Mode Rejection)   Adjustable to 30,000:1 (90 dB) at 60 Hz
Noise   4 µV peak to peak, referred to input, inputs shorted, 3 kHz bandwidth
Output
Type   Single-ended, clipped at approximately 10 volts peak to peak
Output Impedance   500 ohms
Output DC Level   Adjustable to zero
Terminals   BNC front and rear panels
Trace Restorer   Pushbutton control to return output to 0 volts
Calibrator
Range   12 values from 10 µV to 50 mV in 1, 2, 5 steps; ±2% accuracy
Internal Calibration   Pushbutton actuated, DC voltage
Physical Size
CP511 Bench-top   8.63"W x 3.5"H x 8.5"D
(21.9 cm x 8.9 cm x 21.6 cm
)
Weight   2.5 lbs. (1.2 kg)
To Rackmount   Order kit CPRK1 for a single amplifier, or CPRK2 for mounting two amplifiers side by side
P511 Rackmount   19"W x 1.75"H x 8.25"D
(48.3 cm x 4.5 cm x 21 cm)
Weight   3 lbs. (1.3 kg)
Regulatory
 P511 & CP511   ETL listed to UL2601.1 and CSA 22.2 #601.1
    CE marked to MDD, Class IIa, I, Type B

Model P511 rackmount style


Model CP511 bench-top style

FEATURES & BENEFITS
Amplification from 50 to 200,000 allows processing a wide range of AC bioelectric signals
Low Noise improves signal fidelity and resolution
Built-in 12-position Calibrator simplifies calibration and verifies performance
Nine High Pass and Six Active 4-Pole Low Pass Filters tailor the bandwidth to the signal, improve the signal-to-noise ratio and optimize the A/D process
Optional High Impedance Probe provides interface for microelectrodes
MEDICAL-GRADE POWER SUPPLIES
The P511 and CP511 amplifiers must be used with a Grass medical-grade regulated power supply which provide highly regulated ±12 VDC.
 
OPTIONAL HIGH IMPEDANCE PROBE

NEW Model HZP
The HZP High Impedance Probe is intended to provide very high input impedance when interfacing microelectrodes and other high impedance devices to Grass amplifiers. It is generally intended for extracellular microelectrode recording applications, but can be used for interfacing other high impedance devices. The unit also incorporates a switching circuit that provides selection of either recording or stimulating through the same electrode.

Model HZP Specifications

P511 ORDERING INFORMATION

Model P511

  AC physiological preamplifier, 19" rackmount cabinet, includes F-P5IC3/REV1 input cable and manual (power supply required)
Model RPS312RM   Medical-grade power supply for up to 16 channels, 19" rackmount cabinet
Optional Accessories:
Model SRS   Stimulate/Record Switching Unit
Model
F-P5IC3/REV1
  Spare 3-lead input cable, 16-foot length (4.8 m)
Model HZP   High impedance Probe, single channel
Model CAB-51755   Power supply cable for "daisy-chaining" power to additional amplifiers
    See also: rackmount cabinets and carts
CP511 ORDERING INFORMATION
Model CP511   AC physiological preamplifier, bench-top cabinet, includes F-P5IC3/REV1 input cable, manual and power supply cable (power supply required)
Model RPS312   Medical-grade power supply, bench-top module
Optional Accessories:
Model SRS   Stimulate/Record Switching Unit
Model
F-P5IC3/REV1
  Spare 3-lead input cable, 16-foot length (4.8 m)
Model HZP   High impedance Probe, single channel
Model CAB-51755   Power supply cable for "daisy-chaining" power to additional amplifiers
Model CPRK1   Rackmount conversion kit to mount one CP series amplifiers in 19" rack
Model CPRK2   Rackmount conversion kit to mount two CP series amplifiers side-by-side in 19" rack