Page 1 2 [3]
PolyVIEW® 16
General Purpose Data Acquisition & Analysis System
SPECIFICATIONS
Recording Module
Channel Setup Features   Calibration — From volts or mm to user defined units
  Ten built-in Event Marker Text Buffers — Ten user-defined text buffers for one touch event annotation, plus one "on-the-fly" marker
  Sample Rate Range — 0.1 to 25,000 sample/sec, each channel (8-channel) 0.1 to 12,500 sample/sec, each channel (16-channel)
  DSP Functions — d/dt, Integration, Low Pass Filter, Tachograph
  Recording Duration — User defined in seconds, minutes, hours or number of samples
Display Features   Display — One touch display on/off
  Chart Speed — 1 mm/hr to 100 mm/sec (simulated)
  Line Styles — 5 styles
  Color — Any color supported by Windows®
  Values — Instantaneous values displayed on-screen
  DSP Function Parameters — Modify trigger levels, filter cutoffs
Analysis Module
On-screen Measurements (uses two on-screen cursors)   Interactive Measurements — delta Y, delta T, 1/delta T (frequency), slope
  Additional Calculations — Minimum, maximum, mean, standard deviation, integral, area, rate, BPM (beats per minute), peak-to-peak value
  Measurements can be saved to ASCII log file
Analysis   Trend — Mean, min/max, integration (power spectrum)
  FFT (Spectral Analysis) Windows
a. Window filtering — None (uniform), Hann, Hamming, Blackman-Harris, Exact Blackman, Blackman, Flat Top, 4 Term B-Harris, 7 Term B-Harris
b. Display Units — Vrms2, Vpk2, Vrms2/Hz, Vpk2/Hz
c. Display Type — Linear or logarithmic (dB)
d. Digital Values — Total power, estimated peak power and estimated peak frequency
  Zoom
a. Filter Types — Low Pass, High Pass, Band Pass, Band Stop
b. Start/Stop Frequencies — 0.1 Hz to 500 Hz
c. Filter Order — 1 to 10
  X-Y Plotter — Plot any channel segment against any other channel
Display Features   Plot Properties — Color, Pen width, Point style
  DSP Functions — d/dt, Integration, Low pass filter, Tachograph
  Y-Scale Control — Autoscale: always, once, never: Manual control: Log scale on/off
  Scales — Linear, Log (dB)

SPECIFICATIONS (continued)
Scope Mode
Four Channels   

Input Range of ±5 volts

  Maximum Sample Rate of 50 kHz
Vertical Resolution   16 bits
Trigger   Modes — Continuous (Auto), Normal, Single
  Source — External TTL
  Controls — Level (±5 volts), Rising/Falling Edge
Time Base Range   0.1 ms/div to 100 ms/div
Real-time Computed Math Channels   Channel 1 + Channel 2
Channel 1 - Channel 2
Channel 1 x Channel 2
Channel 1 ÷ Channel 2
Minimum
Maximum
Average: 16, 64 or 256 Sweeps
Envelope
Save/Recall Screen Data to Disk   ASCII format
On-Screen Cursor Measurements   Time, voltage, delta T, delta V, minimum, maximum
 

Minimum Hardware/Software Requirements

• Minimum: Pentium processor
• 256 MBytes of RAM minimum
• 200 MBytes hard disk space
• Windows 2000/XP

Recommended Hardware/Software Requirements

• Recommended: Pentium IV processor
• 512 MBytes of RAM recommended
• 1 GByte hard disk space
• Windows 2000/XP

 
Components of PolyVIEW System
• Software Modules for recording and analyzing data
• Data Aquisition Module (plug-in card)
• BNC Adaptor Module
• Users Manual

 

 