Model
1578, 1583, 1579, & 1588
No false
paradoxical respiration
Accurate depiction of building respiration
Improved hypopnea detection
Works synergistically with nasal pressure
Easy application
Affordable
Latex Free
This 2-channel
kit provides the recording of respiratory effort from chest and
abdomen using two transducers.
A single transducer
can be purchased for applications requiring one channel of respiration
effort recording.
Note: Quantum
effort sensors are non-referenced and produce bipolar µV level signals.
Proper signal processing requires AC coupled, referenced differential
amplifiers.
|
| SPECIFICATIONS |
|
Quantum
Effort Sensor
|
| Sensor
Technology |
|
Conductive
Elastomer |
| Power
Requirements |
|
Provided
by Quantum Wireset or Synchrony Module |
| Typical
Signal Amplitude |
|
600
µV peak to peak
Typical signal amplitudes may vary, dependent on sensor placement,
polygraph characteristics, etc. |
| Output
Impedance |
|
500
ohms to 9 kohms, depending on sensor size
Non-referenced, bipolar output |
| Standard
Connector Type |
|
Male
ECG style snaps |
| Sizes
|
|
Size 1: 10" to 16" (25.4 to 40.7 cm)
Size 2: 15" to 25" (38.1 to 63.5
cm)
Size 3: 24" to 35" (61 to 88.9 cm)
Size 4: 34" to 50" (86.4 to 127 cm)
Size 5: 49" to 75" (124.5 to 190.5 cm) |
| Weight |
|
Size 1: 1.8 oz. (50.4 g)
Size 2: 2.3 oz. (64.4 g)
Size 3: 2.8 oz. (78.4 g)
Size 4: 3.2 oz. (89.6 g)
Size 5: 4.8 oz. (138.4 g) |
| Warranty |
|
6-month |
| Quantum
Wireset |
| Function
|
|
Constant
Current Source |
| Battery
Life |
|
Over
three years |
| Power
Requirements |
|
Internal
1.5-volt battery |
| Output
Filtering |
|
Low
pass, approximately 10 Hz with a size 3 sensor |
| Connector
Type |
|
Sensor end: female ECG style snaps |
| Size
|
|
94
±4 inches length |
|
|
| ORDERING
INFORMATION |
| Model
1578 |
|
Quantum
Effort 2-Channel Adult Start-up Kit Includes:
(2) 1091 Wiresets,
(2) 1575-003 Size 3 Effort Belts,
(2) 1575-004 Size 4 Effort Belts,
(2) 1575-005 Size 5 Effort Belts |
| Model
1583 |
|
Quantum
Effort 2-Channel Adult Starter Kit Includes:
(2) 1091 Wiresets,
(2) 1575-004 Size 4 Effort Belts |
| Model
1579 |
|
Quantum
Effort 2-Channel Pediatric Start-up Kit Includes:
(2) 1091 Wiresets,
(2) 1575-002 Size 2 Effort Belts,
(2) 1575-003 Size 3 Effort Belts |
|
Model 1588 |
|
Quantum
Effort 2-Channel Pediatric Starter Kit Includes:
(2) 1091 Wiresets,
(2) 1575-002 Size 2 Effort Belts |
| Replacement
Accessories |
| Model
1575-001 |
|
Sensor,
Size 1: 10" to 16"
(25.4 to 40.7 cm) |
| Model
1575-002 |
|
Sensor,
Size 2: 15" to 25"
(38.1 to 63.5 cm) |
| Model
1575-003 |
|
Sensor,
Size 3: 24" to 35"
(61 to 88.9 cm) |
| Model
1575-004 |
|
Sensor,
Size 4: 34" to 50"
(86.4 to 127 cm) |
| Model
1575-005 |
|
Sensor,
Size 5: 49" to 75"
(124.5 to 190.5 cm) |
| Model
1091 |
|
Quantum
Wireset |
|
|
|
|
Model
1580
|
|
|
Simplified:
Hypopnea detection, Identification of upper airway resistance,
Central event recognition |
|
|
Easy
and effective in pediatric/infant studies |
|
|
Calibrated
and consistent in all body positions |
|
|
Comfortable,
easy to use and affordable |
|
This 2-channel kit provides the recording of respiratory effort
from chest and abdomen. A synchrony module which sums the
chest and abdomen signals as a third channel is also included.
|
| SPECIFICATIONS |
| Functions
|
|
Provides
current source, amplification, and summing for two Quantum
sensors |
| Controls
|
|
One
calibration/battery check push button |
| Displays
|
|
One
calibration/battery check bi-color (green/red) LED |
| Inputs
|
|
Two
EZ glide connectors for interface cables to thoracic and abdominal
sensors |
| Output
|
|
Three:
thoracic, abdominal, and QSUM (voltage sum of thoracic and abdominal
signals) |
| Output
Levels (typical) |
|
600
µV peak to peak for thoracic and abdominal channels, 1200 µV
peak to peak for the QSUM channel |
| Output
Impedance |
|
Static:
51 kohms |
| Output
Filtering |
|
First
order, low pass, corner frequency = 10 Hz |
| Output
Cable Connectors |
|
1.5
mm touch-proof safety connectors on 7" cables (17.8 cm) |
| Physical
Size |
|
2"
W x 0.8" H x 2.75" L
(5.1 cm x 2.0 cm x 7.0 cm) |
| Weight
(with battery) |
|
0.129
lbs. (58 g) |
| Power
Source |
|
Battery,
3.6-volt lithium, non-replaceable |
| Battery
Life (calculated) |
|
Three plus years under normal usage |
|
|
| ORDERING
INFORMATION |
| Model
1580 |
|
Quantum
Synchrony, 2-channel Adult Startup Kit includes: Synchrony Module,
Synchrony Wireset, 2 each sensors size 3, 4, 5 |
| Replacement
Accessories |
| Model
1575-001 |
|
Sensor,
Size 1: 10" to 16"
(25.4 to 40.7 cm) |
| Model
1575-002 |
|
Sensor,
Size 2: 15" to 25"
(38.1 to 63.5 cm) |
| Model
1575-003 |
|
Sensor,
Size 3: 24" to 35"
(61 to 88.9 cm) |
| Model
1575-004 |
|
Sensor,
Size 4: 34" to 50"
(86.4 to 127 cm) |
| Model
1575-005 |
|
Sensor,
Size 5: 49" to 75"
(124.5 to 190.5 cm) |
| Model
1577 |
|
Synchrony
Module with 2 Synchrony Wiresets |
| Model
1092 |
|
Replacement
Synchrony Wireset
|
|
These
devices are for diagnostic purposes only and not for use with or as apnea
monitors.
|